Medical device testing for CDSCO, CE and export approvals.
Electrical safety and EMC to IEC 60601, ISO 10993 biocompatibility, sterility, endotoxin, sterilisation validation, packaging and device performance. We plan the tests around your CDSCO filing, use CDSCO-registered and accredited labs, and review reports before submission.
Testing that supports your CDSCO licence
Electrical Safety & EMC
IEC 60601-1 general safety, IEC 60601-1-2 EMC and the particular standard for your device, or IEC 61010 for lab and IVD equipment.
Biocompatibility
ISO 10993 tests chosen by body contact and duration, from cytotoxicity and sensitisation to chemical characterisation.
Sterility & Performance
Sterility, endotoxin, sterilisation validation, packaging and shelf life, plus device-specific performance tests.
Medical device testing: the key facts
| What we do | Arrange medical device and IVD testing at CDSCO-registered and NABL-accredited labs, and plan it with your CDSCO filing |
| Regulation | Medical Devices Rules, 2017; laboratories registered for testing under Chapter X (Form MD-40) |
| Key standards | IEC 60601-1 / IS 13450, IEC 60601-1-2, IEC 61010-1, ISO 10993 series, ISO 11135, ISO 11137, ISO 11607, ASTM F1980 |
| Reports used for | CDSCO import and manufacturing licences, CE, US FDA, tenders. See CDSCO registration |
| Consultant | Bizpro Compliance Services, New Delhi, arranges medical device testing at NABL-accredited and ILAC-recognised labs across India for manufacturers, importers, exporters and government suppliers: +91 920 500 6364, contact@bizprocompliance.com |
Medical device tests and standards we arrange
Safety, biocompatibility, sterility, packaging and performance tests for medical devices and IVDs. Search by device or test.
Showing all 19 tests and standards
| No. | Test | Standard | Used For | |
|---|---|---|---|---|
| 1 | Electrical Safety of Medical EquipmentBasic safety and essential performance of medical electrical equipment | IEC 60601-1 / IS 13450 | CDSCOCEExport | |
| 2 | Medical EMCElectromagnetic compatibility of medical devices | IEC 60601-1-2 | CDSCOCE | |
| 3 | Home Healthcare EquipmentSafety for devices used at home | IEC 60601-1-11 | CDSCOCE | |
| 4 | Particular Standards (60601-2-x)Device-specific safety, e.g. infusion pumps, monitors, ventilators | IEC 60601-2 series / ISO 80601-2 series | CDSCOCE | |
| 5 | Laboratory & IVD Equipment SafetySafety of lab, diagnostic and IVD instruments | IEC 61010-1 / IEC 61010-2-101 | CDSCOCE | |
| 6 | CytotoxicityIn vitro cell toxicity of device materials | ISO 10993-5 | CDSCOCEFDA | |
| 7 | Sensitisation & IrritationSkin sensitisation and irritation potential | ISO 10993-10 / ISO 10993-23 | CDSCOCEFDA | |
| 8 | Systemic Toxicity & ImplantationAcute and sub-chronic toxicity, implantation effects | ISO 10993-11 / ISO 10993-6 | CDSCOCEFDA | |
| 9 | HaemocompatibilityBlood interaction of devices | ISO 10993-4 | CDSCOCE | |
| 10 | Chemical Characterisation & ExtractablesExtractables and leachables of device materials | ISO 10993-18 | CDSCOCEFDA | |
| 11 | Sterility TestingSterility of sterile devices | ISO 11737-2 / IP / USP 71 | CDSCO | |
| 12 | Bacterial Endotoxin (LAL)Pyrogen and endotoxin levels | USP 85 / IP methods | CDSCO | |
| 13 | BioburdenMicrobial load before sterilisation | ISO 11737-1 | CDSCOCE | |
| 14 | Sterilisation Validation (EO / Gamma)Ethylene oxide residues and radiation dose validation | ISO 11135 / ISO 11137 / ISO 10993-7 | CDSCOCE | |
| 15 | Packaging & Shelf LifeSeal strength, integrity and accelerated ageing | ISO 11607 / ASTM F1980 / ASTM F88 | CDSCOCEFDA | |
| 16 | Syringes, Needles & CathetersPerformance tests for single-use devices | ISO 7886 / ISO 7864 / ISO 10555 | CDSCOBIS | |
| 17 | Gloves, Masks & GownsBarrier, filtration and physical performance | IS 15354 / IS 16289 / EN 14683 / ASTM F2100 | CDSCOBIS | |
| 18 | Thermometers & BP MonitorsAccuracy and performance of measuring devices | ISO 80601-2-56 / IEC 80601-2-30 | CDSCO | |
| 19 | Medical Device SoftwareSoftware life cycle and usability documentation review | IEC 62304 / IEC 62366-1 | CDSCOCE |
“” isn’t in this list
We arrange many more tests than are listed here. Tell us the product and the standard or specification, and we’ll confirm the lab and cost.
Tell us what the product is and we’ll confirm which approvals it needs, free.
Standards are listed by their current published reference; the exact edition is confirmed against your specification or the authority’s requirement before testing. Tests run at NABL-accredited and ILAC-recognised partner labs whose scope covers them.
Get your medical device testing quote and timeline
Tell us the product and the standard, specification or approval you’re testing for. A specialist confirms the test plan, lab, total cost and turnaround, in writing.
- Reply within one business dayFrom a named consultant, not an automated sales sequence.
- Fixed written quoteGovernment fees, lab charges and our fee listed separately before you commit.
- Accredited labs across IndiaNABL / ILAC reports accepted by regulators and buyers.
What medical device testing costs
One written quote covering every test, so there are no surprises when the report is issued.
Request received
Thanks. A BIS specialist will reply within one business day with your standard, test plan, cost and timeline.
Send it with one tap instead
The form couldn’t send just now. Your details are ready in a message, so you only need to press send.
Your medical device testing in five steps
Medical testing is planned from your device’s classification, intended use and body contact, so you test once for CDSCO and export.
Standard & Test Plan
We confirm exactly which standard, clauses and tests apply, and why: certification, tender, export or customer approval.
Day 1Lab & Fixed Quote
We choose a lab whose accreditation scope covers your tests and send one written quote with cost and turnaround.
Day 1–3Samples & Documents
You send samples, datasheets and any drawings or specs. We check quantities so testing isn’t held up.
Day 3–7Testing & Updates
The lab tests to the plan. Early failures are flagged straight away so you can fix and retest quickly. Witnessing on request.
As quotedReport Review
We check the report against the standard and the authority it’s for before you submit it, then help with the next filing.
On completionWhy manufacturers use us for medical device testing
Right Lab, First Time
We match your tests to a lab whose accreditation scope actually covers them, so the report is accepted by BIS, TEC, CDSCO, RDSO, a buyer or a tender committee.
One Point of Contact
Test plan, quotes, samples, follow-ups and report review are handled by one specialist, not passed between lab departments.
Testing Linked to Certification
Reports are planned for the approval you need next, from BIS and TEC to CE and FCC, so you don’t pay to test twice.
Medical device testing for businesses across India
We work with CDSCO-registered and NABL-accredited medical device labs across India, and support manufacturers in medical device parks and clusters, including:
Common medical device testing mistakes
No Biological Evaluation Plan
Running every ISO 10993 test is costly; skipping one CDSCO expects causes queries. Plan first.
Lab Not Registered for Your Device
CDSCO lab registrations list specific devices and tests. Check before sending samples.
Testing Pre-Production Units
Samples must represent the final design, materials and sterilisation process.
Shelf Life Without Ageing Data
A claimed shelf life needs accelerated ageing and packaging integrity data to back it.
Other testing we arrange
Electrical Testing
Safety, performance, temperature rise, IP and type tests for electrical products. See Electrical Testing.
Chemical Testing
RoHS, REACH, heavy metals, composition, water and material analysis. See Chemical Testing.
EMC Testing
Emission and immunity testing to CISPR, IEC 61000, MIL-STD-461 and railway EMC. See EMC Testing.
ASTM Testing
Mechanical, material, coating, packaging and petroleum tests to ASTM methods. See ASTM Testing.
NABL / ILAC Accredited Testing
Accredited reports accepted by Indian regulators and overseas buyers. See NABL / ILAC Accredited Testing.
Client Specification Testing
Testing to your tender, OEM, RDSO or MIL-STD-810 specification. See Client Specification Testing.
Common questions about medical device testing
Which medical device tests does CDSCO require?
Which labs can test medical devices for CDSCO?
What is IEC 60601-1 testing?
What is ISO 10993 biocompatibility testing?
Do I need a test licence to test a medical device?
How long does medical device testing take?
Can foreign test reports be used for CDSCO?
Get your medical device testing planned properly
Tell us the product and the standard or approval it’s for. We’ll confirm the tests, lab, total cost and turnaround in writing, free.